Skip to main content
Are Sockets In Skirting Boards Illegal?

Are Sockets In Skirting Boards Illegal?

Not sure? We'll check for you.

Not illegal to keep, but they usually mean old wiring, so the thing to do is test the circuit, not move the socket.

Medium

Blake FolgadoUpdated

What's happening?

Sockets set into the skirting board are not illegal to keep. Electrical Safety First says there is no legal requirement to replace them in an older property, but because the wiring is likely to be old it advises a registered electrician to inspect the installation and issue an EICR. It lists sockets mounted in skirting boards as one of the signs to look for in a home with old electrics. For new or rewired installations, its wiring regulations guidance says BS 7671 requires every 13 A socket in a home to be RCD protected, which old circuits often lack. So the socket is the clue and the circuit is the question. If the EICR passes it, the sockets can stay. If not, the cure is rewiring that circuit, and the sockets move as part of the job.

What usually causes it?

  • A house wired decades ago and never rewired
  • Old round-pin or early square-pin sockets on the same circuits
  • A circuit that has been extended or added to over the years
  • No RCD protection on the circuit, because the consumer unit has rewirable fuses or no RCD
  • A cable that comes up from under the floor to a socket with no visible protection

Is it dangerous?

Not on its own: the height of a socket does not make it unsafe. It is a sign that the wiring behind it may be old, and old wiring is where the risk is. Cracked, scorched or loose sockets, or a consumer unit with rewirable fuses and no RCD, change the answer.

Can I fix it myself?

Not the wiring. You can look for burn marks, cracks, crackling or warm faceplates, and check whether the consumer unit has an RCD with a test button. If it has none, or it is not working, Electrical Safety First advises plug-in RCDs for the sockets in the meantime.

When should you call an electrician?

Call when the house has sockets at skirting height and no recent EICR, or when you are buying one. Call sooner if any socket is damaged, warm or has scorch marks, or if the consumer unit is old.

What will the electrician actually do?

  • Inspect and test the circuits feeding the low sockets, including earth continuity and insulation resistance
  • Check whether the circuit has RCD protection and whether the RCD trips when tested
  • Check the condition of the cable where it can be seen and the type of cable in use
  • Issue an EICR with a code against anything that is not satisfactory
  • Quote the choice the results leave: leave them, replace the circuit, or rewire part of the house and fit the sockets higher

Who fixes this

What it usually costs

EICR Cost
£100–£330

Questions people ask

Are sockets in skirting boards illegal?

No. Electrical Safety First says there is no legal requirement to replace sockets positioned on skirting boards in an older property. It does advise an inspection by a registered electrician, because the wiring is likely to be old.

Will sockets in skirting boards fail an EICR?

The position alone does not decide it. The EICR records the condition of the installation, and Electrical Safety First treats low sockets as a sign to look further rather than as a breach.

Does a socket in a skirting board need RCD protection?

Electrical Safety First's wiring regulations guidance says new or rewired installations must have RCD protection on every 13 A socket in a home under BS 7671. An older circuit often has none, which is one thing the EICR will show.

Can I have my low sockets moved up the wall?

Yes, but the electrician will test the circuit first. If the cable is sound it can be extended or re-run to the new position. If it is not, moving the socket is the moment to replace that circuit.

Sources & References

  1. Electrical Safety First: RCDs explained (signs of old sockets)
  2. Electrical Safety First: older and vulnerable people (sockets on skirting boards)
  3. Electrical Safety First: Wiring Regulations Help, new and rewired installations