No RCD On An EICR: Does It Fail?
Not sure? We'll check for you.
Medium
What's happening?
Not having an RCD does not automatically fail an EICR, but it often does. What counts is which circuit lacks the protection. The inspector codes it C2, which fails the report, where a socket could supply portable equipment used outdoors, or a socket sits in a room with a bath or shower. They code it C3, a recommendation that does not fail the report, where the socket is unlikely to feed outdoor equipment, or where only lighting circuits or cables buried in walls lack the protection. BS 7671 expects 30mA RCD protection on socket-outlets up to 32A, so an older board with no RCD at all will usually raise several of these items at once. A faulty main RCD, one that does not trip on test, is a C2 in its own right.
What usually causes it?
- A pre-RCD fuse box with rewirable or cartridge fuses and no residual current protection
- A split-load board where only some circuits are behind the RCD
- An external plug-in RCD relied on in place of protection at the board
- A new socket or outdoor supply added to an old circuit with no RCD
- A main RCD that has stopped working or has never been tested
- Lighting circuits, which since BS 7671:2018 should have additional protection in homes, left without it
Is it dangerous?
An RCD is what cuts the power fast enough to stop a shock from being fatal when something goes to earth. Without it a person touching a faulty appliance or cable relies on the fault clearing by other means. Press the test button on any RCD you have every few months, and treat one that fails to trip as a fault.
Can I fix it myself?
Pressing the RCD test button is fine and worth doing. Anything else is for an electrician: fitting RCD protection means changing the consumer unit or individual circuit protection and certifying it.
When should you call an electrician?
Call as soon as the EICR says no RCD, or if the test button does nothing. Ask them to say, circuit by circuit, which items are C2 and which C3, and to quote the board change that clears them. For a landlord in England, C2 items must be fixed within 28 days or sooner if the report says so.
What will the electrician actually do?
- Check which circuits have RCD protection and whether it trips in the required time
- Explain the C2 and C3 items on the circuits without protection
- Replace the consumer unit with RCBO or RCD-protected circuits where the old board cannot take them
- Test every circuit that is reconnected
- Issue an Electrical Installation Certificate and confirm the C2 items are cleared
Who fixes this
What it usually costs
- Fuse Box Replacement Cost
- £500–£1,500 for a three-bed semi
- EICR Cost
- £100–£330
Questions people ask
Does no RCD fail an EICR?
My consumer unit has no RCD, will my EICR be unsatisfactory?
Can I just plug in an RCD adaptor instead?
Do I need a new fuse box to get an RCD?