Boiler Flue Too Close to a Window or Boundary
Not sure? We'll check for you.
Medium
What's happening?
Approved Document J, the England Building Regulations guidance on combustion appliances, gives minimum distances from a gas boiler flue outlet. For a fanned-draught balanced flue, which your engineer can confirm, the outlet should be at least 300mm below, above or beside an openable window or air vent, at least 300mm from a boundary alongside it, and at least 600mm from a boundary or surface facing it. Smaller boundary distances may be acceptable if the appliance is shown to operate safely. The HSE says the regulations require flues in a safe position at specified distances from the boundary, and that some installations that do not comply still operate safely. If you are worried, it says to get a Gas Safe registered engineer to examine the flue.
What usually causes it?
- A boiler flue fitted too near an opening window when it was installed
- A replacement boiler whose flue was moved, or whose outlet is in a different place
- A new window put in near an existing flue
- A neighbour's extension, fence or wall built close to the outlet
- A flue on a side wall right on the boundary
- A flue outlet facing a wall or fence
Is it dangerous?
The distances exist so that the products of combustion disperse and a balanced flue can draw in clean air, according to Approved Document J. A flue too close can send fumes back towards a window or a neighbour's property. The HSE says around 7 people a year die from gas-related carbon monoxide poisoning, so fit an alarm and have the flue examined.
Can I fix it myself?
No flue or boiler work. Do not block, cover or box in the outlet. Talk to your neighbour if the issue is a boundary, because the HSE advises neighbours and householders to consult before work starts. Fit a carbon monoxide alarm and ask a Gas Safe registered engineer to examine the flue.
When should you call a gas engineer?
Call a Gas Safe registered engineer when the outlet looks close to a window, an air vent or the boundary, when a neighbour is building near it, or after a new window or extension. If a carbon monoxide alarm sounds, leave the property and use the carbon monoxide alarm page first.
What will the gas engineer actually do?
- Identify the type of flue and the boiler's heat input
- Measure the outlet to windows, vents, boundaries and surfaces against Approved Document J and the manufacturer's instructions
- Test combustion and check the flue for carbon monoxide
- Where it is too close, move the outlet with a flue extension or re-route it to a compliant position
- Record what was found and done, and tell you if the position is not acceptable
Who fixes this
What it usually costs
- New Boiler Cost
- £1,400–£7,000
Questions people ask
How close can a boiler flue be to a window?
Can a boiler flue be on the boundary with my neighbour?
My neighbour is building an extension near my boiler flue. What should I do?
Can the steam from a neighbour's boiler flue be a nuisance?