Skip to main content
Boiler in a Bedroom: Is It Legal?

Boiler in a Bedroom: Is It Legal?

Not sure? We'll check for you.

A room-sealed boiler can be in a bedroom; most other types cannot.

Medium

Blake FolgadoUpdated

What's happening?

The Gas Safety (Installation and Use) Regulations 1998 limit gas appliances in sleeping rooms. The HSE says that since 31 October 1998 a room converted to sleeping accommodation should not contain a gas boiler over 14 kilowatts unless it is room-sealed, and a boiler of 14 kilowatts or less unless it is room-sealed or has an atmosphere-sensing device. A room-sealed appliance has its combustion sealed off from the room and takes its air from outside the room. The rule covers a cupboard inside the room, and a cupboard next door that has an air vent into the bedroom. For a bedroom that existed before 1998, the HSE says the landlord needs to risk-assess whether it can still be used. A Gas Safe registered engineer can tell you which type you have.

What usually causes it?

  • A boiler in an airing cupboard that opens into a bedroom
  • A loft conversion or extension that put a bedroom round an existing boiler
  • A room converted to a bedroom with the old boiler left in it
  • An older boiler that takes its air from the room rather than outside
  • A boiler in a cupboard next door with an air vent into the bedroom

Is it dangerous?

It can be. A boiler that takes its air from the room and is not working properly can give off carbon monoxide where people sleep. The HSE says around 7 people a year die from gas-related carbon monoxide poisoning. A carbon monoxide alarm is a back-up and does not make an unsuitable boiler position acceptable.

Can I fix it myself?

No gas work. Check the make and model with a Gas Safe registered engineer, who can say whether it is room-sealed. Fit a carbon monoxide alarm in the bedroom. If you rent, ask your landlord for the latest gas safety record and whether the room was a bedroom before 1998.

When should you call a gas engineer?

Call a Gas Safe registered engineer when the boiler is in or opens into a bedroom and you do not know whether it is room-sealed, when you are converting a room to a bedroom, or when a loft or extension is going round a boiler. If the boiler is not room-sealed and the room is used for sleeping, ask for a quote to move or replace it.

What will the gas engineer actually do?

  • Identify whether the boiler is room-sealed or takes air from the room, and its heat input
  • Check the flue, any air vents and the cupboard it sits in
  • Test combustion and check for carbon monoxide
  • Advise whether it can stay, or quote to replace it with a room-sealed boiler or move it to another room
  • Where it is unsafe, make it safe and issue the unsafe-situation notice

Who fixes this

What it usually costs

New Boiler Cost
£1,400–£7,000

Questions people ask

Is it legal to have a boiler in a bedroom?

The HSE says a room converted to a bedroom since 31 October 1998 should not contain a gas boiler unless it is room-sealed, with a lower-rated boiler also allowed if it has an atmosphere-sensing device. A room-sealed boiler is not the problem.

Is a boiler in a bedroom safe?

A room-sealed boiler is the safe type for a bedroom, because the regulations define it as having its combustion sealed from the room and its air from outside the room. A boiler that takes air from the room is the one that should not be there.

Does a boiler cupboard in the bedroom count?

Yes. Regulation 30 treats a cupboard within the room, and a cupboard next to it with an air vent into the room, as part of the room.

I rent and the boiler is in the bedroom. What can I do?

The HSE says that if the room was a bedroom before 1998 your landlord needs to carry out a risk assessment, and you can ask for a Gas Safe registered engineer to check the appliance. Landlords must also have a gas safety check every 12 months.

Sources & References

  1. HSE: domestic gas, frequently asked questions
  2. The Gas Safety (Installation and Use) Regulations 1998, regulation 30: room-sealed appliances
  3. The Gas Safety (Installation and Use) Regulations 1998, regulation 2: interpretation