White Smoke From the Boiler Flue
How much to fix yours?
Usually £156
Low risk · Fixed by a heating engineer
Key takeaways
- A white plume from a condensing boiler's flue is normal and not a fault.
- It is most visible in cold, still weather and disappears in warm weather.
- A carbon monoxide alarm, soot staining or a burning smell is not normal. Switch off and call 0800 111 999 for gas.
- A plume kit can move it away from a path, wall or neighbour.
What's happening?
A condensing boiler squeezes extra heat out of its exhaust, so the gases leave the flue much cooler than from an old boiler. Worcester Bosch says condensing flue gases leave at about 55 degrees Celsius, which is why on some days a white plume can be seen at the flue terminal: the water vapour in the exhaust cools quickly outside and condenses, like breath on a cold morning. Glow-worm's manual says the same: like all condensing boilers, the appliance will produce a plume of condensation from the flue terminal in cool weather, and this is normal and not a fault indication. You will see more of it in winter, on still days and when the boiler is working hardest.
What usually causes it?
- Normal condensation from a condensing boiler's cool flue gases in cold weather
- The boiler working harder, for hot water or on a cold morning, so more vapour is produced
- A flue terminal sited so the plume drifts across a path, window or neighbour's wall
- An older non-condensing boiler whose flue gases were hot enough that the plume was rarely visible, so a newer one looks different
- A different problem altogether if there is also a smell, soot or an alarm: see the safety answer
Is it dangerous?
A white plume of condensation is not dangerous. White vapour is not the warning sign for carbon monoxide: the NHS says carbon monoxide has no colour or smell, which is why an alarm matters. Treat soot or brown staining at the flue, a smell of burning or gas, or a carbon monoxide alarm sounding as an emergency: turn the appliance off, get out of the house and call the National Gas Helpline on 0800 111 999.
Can I fix it myself?
Nothing needs fixing. Check that it is only white and wispy, that it clears in a few metres and that it only appears in cool weather. If the plume blows onto a path, door or neighbour's window, a plume management kit from the boiler's maker can redirect it, and a Gas Safe registered engineer should fit it because it changes the flue. Do not block, cover or modify the terminal yourself.
When should you call a heating engineer?
Call a Gas Safe registered engineer if the plume has appeared on a boiler that never made one and the boiler is also showing a fault, if there is soot or brown staining around the terminal, if a carbon monoxide alarm has sounded, or if you want the plume moved because it is a nuisance. The engineer checks the flue run and terminal position against the manufacturer's installation manual.
What will the heating engineer actually do?
- Check the flue terminal for blockages, damage and correct position
- Inspect the whole flue run for sound joints and correct fall
- Check the boiler's combustion with a flue gas analyser
- Fit a manufacturer plume management kit where the plume is a nuisance
- Confirm the condensate pipe is clear and not frozen
Who fixes this
What it usually costs
Questions people ask
Is white smoke from a boiler flue dangerous?
Why can I see steam from my boiler flue only in winter?
Can I stop the plume?
What if the white plume is very thick or constant?
Sources & References
Before you book, read how to check a heating engineer is registered.