Skip to main content
Heat Pump Noisy At Night

Heat Pump Noisy At Night

Not sure? We'll check for you.

Most heat pump noise complaints come down to where the unit sits and how it is mounted, so the fix is often moving or isolating it.

Low

Blake FolgadoUpdated

What's happening?

A government review of heat pump noise found that many noise complaints relate to where the outdoor unit is placed and how close it is to neighbouring properties. Some people also felt vibration from a nearby unit through their walls. Manufacturers described the usual measures to the review: anti-vibration mounts and platforms, flexible pipe connections, not fixing the unit to a house wall, and quiet modes. Manufacturers told the review that quiet modes cut the heat pump's output by 10 to 30%, so the house may not stay warm on cold nights. The MCS 020(a) standard sets the permitted development noise limit at 37 dB at a point 1 m outside a neighbour's door or window to a habitable room, calculated without the low noise mode. A heat pump above that is not permitted development.

What usually causes it?

  • An outdoor unit placed close to a bedroom window, a boundary or a reflecting wall
  • A unit fixed rigidly to a wall or on a base with no vibration isolation
  • Rigid pipework that carries vibration into the house
  • A fan or compressor fault, or something loose in the unit or its casing
  • Quiet mode set, which cuts output and leaves the house cold

Is it dangerous?

No. It is a nuisance and a possible dispute with neighbours rather than a safety risk. A new knocking, grinding or squealing from the unit is a different matter and needs an engineer.

Can I fix it myself?

Not the unit. You can note when it is loudest, whether it is a hum, a rattle or a pulse, and whether the sound carries into a room through the wall. Keep the area around the unit clear. Do not switch on quiet mode without checking the house still reaches temperature, because it cuts output.

When should you call a heating engineer?

Call a heating engineer when the noise is new, when it carries into the house, or when a neighbour has complained. Ask for the original MCS noise calculation, and ask them to check the unit and its mounting before anyone suggests moving it.

What will the heating engineer actually do?

  • Listen to the unit running and find whether the noise is the fan, the compressor or vibration
  • Check the mounting, the base and the pipe connections, and fit anti-vibration mounts or flexible connections
  • Check the unit for a fault in the fan or compressor, or loose casing
  • Compare the installation with the MCS 020(a) noise calculation if there is a complaint
  • Quote moving the outdoor unit or adding a barrier where the position is the problem
  • Set the controls so the heat pump runs steadily, and tell you what a quiet mode would cost in output

Who fixes this

  • Heat pump repair
  • Heat pump installation

What it usually costs

Questions people ask

Why is my heat pump noisy at night?

The government's heat pump noise review found most complaints relate to where the unit sits and how close it is to neighbours. Vibration through the mounting or pipework can also carry into the house.

Can I put my heat pump on a quiet mode?

Yes, but manufacturers told the review that quiet modes reduce output by 10 to 30%, so the house may not reach temperature on a cold night. Ask the engineer to check before you rely on it.

How loud is a heat pump allowed to be?

MCS 020(a) sets the permitted development limit at 37 dB at a point 1 m outside a neighbour's door or window to a habitable room. The standard says compliance alone does not give permitted development rights, since other conditions apply.

What if my heat pump is louder than the limit?

Then it is not permitted development under MCS 020(a), and the standard puts a duty on MCS contractors to ensure compliance. Ask your installer for the noise calculation and what they will do if it is not met.

Sources & References

  1. GOV.UK: review of air source heat pump noise emissions, permitted development guidance and regulations
  2. MCS 020(a): air source heat pump sound calculation, issue 1.1
  3. MCS: heat pumps