House Cold Even With The Heating On
Not sure? We'll check for you.
Low
What's happening?
When the heating is on but the house stays cold, the boiler is usually making heat and something is stopping it getting to the rooms or being used properly. It is worth sorting out which of three things you have. If radiators stay cold, heat is not reaching them: look at controls, closed valves, air or sludge. If radiators are hot and the house is still cold, the heat is not enough for the rooms, which can come down to the boiler's flow temperature, unbalanced radiators or the system struggling. If only some rooms are cold, it is a balancing, valve or blockage problem on those radiators. The checks you can do cost nothing and take minutes, and they tell you whether you need an engineer or just a different setting.
What usually causes it?
- Programmer, room thermostat or its batteries stopping the call for heat
- Thermostatic radiator valves closed or seized shut
- Air trapped at the top of radiators, leaving them cold up there
- Sludge settling at the bottom of radiators, so they are cold at the base
- Radiators not balanced, so the nearest ones take all the heat
- A boiler flow temperature set low or a pump not moving water
- A boiler that keeps cutting out and never heats the system fully
Is it dangerous?
Not in itself. A house without heating in a hard frost needs attention before pipes freeze. If you smell gas or fumes or a carbon monoxide alarm sounds, leave and call the emergency service.
Can I fix it myself?
Check the programmer and thermostat settings and change the thermostat's batteries. Open every thermostatic radiator valve. Feel each radiator top and bottom: cold at the top means air, cold at the bottom means sludge. Bleed air from radiators that are cold at the top. Check the boiler's pressure gauge sits in the green. If the radiators are all hot and the rooms are still cold, check the boiler's flow temperature against the manual.
When should you call a heating engineer?
Call a heating engineer when the controls are right and the radiators are still cold, when the boiler cuts out or loses pressure, when several radiators are cold at the bottom, or when no setting you try changes things. Call the same day in freezing weather.
What will the heating engineer actually do?
- Check the boiler is getting a call for heat and running through a full cycle
- Test the pump, valves and controls and replace what has failed
- Free or replace seized radiator valves
- Balance the radiators so the heat is shared between rooms
- Flush the system and fit a magnetic filter where sludge is the cause
- Review the flow temperature and controls, then prove heat to every room
Who fixes this
- Heating not working
- Power flush
What it usually costs
- Power Flush Cost
- £400–£870
Questions people ask
Why is my house so cold even with the heating on?
My radiators are hot but the house is still cold, why?
Why are my radiators cold at the bottom and hot at the top?
Does a cold house mean I need a new boiler?
Sources & References