F22 is the boiler refusing to run without enough water in the circuit. Look at the pressure gauge first: it will usually be below the normal range.

Caution · Fixed by a heating engineer

Sol WrightSol Wright, Co-founder, TradehandPublished Updated

Key takeaways

  • Check the pressure gauge. Vaillant's normal range is 1 to 1.5 bar.
  • If it is below 1 bar and you are competent, repressurise slowly via the filling loop.
  • If it keeps dropping, there is a leak: do not keep topping up.
  • A faulty sensor, pump or expansion vessel can also cause F22: call an engineer.

What's happening?

Vaillant lists F22 as no or insufficient water in the product, or the water pressure being too low. Vaillant UK says the normal pressure range is 1 to 1.5 bar. Below the working pressure the boiler locks out and shows the code. The usual reasons are a leak somewhere in the radiators or pipes, bleeding radiators, or a part that is not working. Vaillant lists a faulty water pressure sensor, a loose or faulty cable to the pump or sensor, a faulty internal expansion vessel and a faulty solenoid valve on the automatic filling device as possible causes.

What usually causes it?

  • System pressure that has dropped from bleeding radiators or a small leak
  • A leak at a radiator valve, joint, pipe or the pressure relief valve
  • A faulty internal expansion vessel, so pressure swings and then falls
  • A faulty water pressure sensor or a loose cable to it or the pump
  • A pump that is not running properly
  • A faulty solenoid valve on the automatic filling device

Is it dangerous?

F22 is not dangerous in itself. The boiler has shut down to protect itself. Do not open the casing. If you find a leak, switch the boiler off at the fused spur. If you smell gas, leave the house and call the National Gas Helpline on 0800 111 999.

Can I fix it myself?

Read the gauge. Vaillant says if it is below 1 bar and you are competent you may repressurise yourself: find the filling loop, which your manual shows, and slowly raise the pressure to between 1 and 1.5 bar. The usual steps are: switch the boiler off and let it cool, check both ends of the filling loop are attached, open the isolation valve, then open the handle valve and watch the gauge, then close the handle valve first and the isolation valve second. Switch the boiler back on. If the pressure falls straight after you close the valve, stop: there is a major leak or a pressure relief valve fault, and Vaillant says not to keep topping up.

When should you call a heating engineer?

Call a Gas Safe registered engineer if F22 returns after repressurising, if pressure keeps falling, if the gauge reads in the normal range and the code remains (which points at the sensor, pump or expansion vessel), or if you find a leak. Vaillant says not to try to solve faults inside the boiler yourself because opening the casing can be dangerous.

What will the heating engineer actually do?

  • Check pressure, then find where the system is losing water
  • Test the expansion vessel pressure and recharge or replace it
  • Test the pressure sensor and its wiring, and replace a faulty sensor
  • Check the pump runs and the filling device solenoid operates
  • Repressurise, bleed the system and test the boiler through a heat cycle

Who fixes this

What it usually costs

Questions people ask

What does F22 mean on a Vaillant boiler?

Vaillant says it means no or insufficient water in the product, or the water pressure is too low. The boiler has locked out until pressure is restored.

How do I fix F22 on a Vaillant boiler?

If the gauge reads below 1 bar and you are competent, repressurise via the filling loop to between 1 and 1.5 bar. If it comes back, call a Gas Safe engineer: it is a leak, sensor, pump or expansion vessel.

Why does F22 keep coming back?

Water is leaving the system, or a part is failing. Vaillant lists a faulty pressure sensor, a faulty internal expansion vessel and faulty wiring or pump among the causes.

Can I just keep topping up the pressure?

Not if it keeps dropping. The Vaillant repressurising guide says if pressure falls as soon as you close the valve there is probably a significant leak, and not to keep repressurising.

Sources & References

  1. Vaillant: F22 fault code
  2. Vaillant UK: boiler fault codes
  3. Vaillant UK: how to repressurise a boiler