Radiator Not Heating Up After Bleeding
How much to fix yours?
Low risk · Fixed by a heating engineer
Key takeaways
- Look at the boiler pressure gauge first: bleeding can drop it too low.
- Top it up via the filling loop to the boiler's normal range, usually 1 to 1.5 bar.
- Check the thermostatic valve and the lockshield valve are both open.
- Cold at the bottom after all that points to sludge. That needs an engineer.
What's happening?
Bleeding a radiator lets trapped air out through the vent, and some water comes with it. On a sealed system that water is not replaced automatically, so the pressure on the boiler gauge falls. EDF Energy says low boiler pressure can stop the heating working across several radiators, because the boiler cannot provide the hot water needed. Vaillant gives the target as around 1 to 1.5 bar for its boilers, and says to check your manual because it varies by model. The air that was in the radiator can also move to another point in the system after the first bleed, so a second bleed is often needed once pressure is restored.
What usually causes it?
- Boiler pressure dropped below the working range after bleeding
- Air that has moved to another radiator or the top of the system
- A thermostatic radiator valve or lockshield valve that was closed or moved
- Sludge or debris, which leaves the bottom of the radiator cold
- A leak that is losing water, so the pressure keeps falling
- A stuck radiator valve pin that is not opening the valve
Is it dangerous?
Not dangerous. Bleed with the heating off and the radiator cool, because the water can be hot, and hold a cloth under the vent. Vaillant says if pressure falls again as soon as you close the filling valves, there is a significant leak or a fault, and you should stop topping up and call a Gas Safe registered engineer.
Can I fix it myself?
Check the pressure gauge. If it is below the boiler's range, repressurise with the filling loop: switch the boiler off and let it cool, check both ends of the loop are attached, open the isolation valve, open the handle valve and watch the gauge rise to about 1 to 1.5 bar, then close both again. Check the thermostatic valve and the lockshield valve are open on the radiator. Switch the heating on and bleed the radiator again if it is still cold at the top. EDF Energy says if it is still cold after all that, look for leaks and consider that the system may need flushing.
When should you call a heating engineer?
Call a heating engineer if the pressure drops again after repressurising, if the radiator is hot at the top and cold at the bottom after bleeding, if the valves will not move, or if several radiators stay cold. Cold at the bottom suggests sludge, and EDF Energy says a power flush should be done by a plumber rather than the homeowner.
What will the heating engineer actually do?
- Check the pressure and where the system is losing water, if it is
- Test whether the radiator valves are opening and replace a stuck pin or valve
- Bleed the whole system and balance the radiators
- Test the radiator and system for sludge and clean it with a chemical or power flush
- Fit a magnetic filter and inhibitor to protect the system afterwards
Who fixes this
- Heating not working
- Power flush
Questions people ask
Why is my radiator cold after bleeding?
How much pressure should the boiler have after bleeding?
Do I bleed the radiator again after repressurising?
What if the radiator is still cold at the bottom?