Radiator Not Heating Up After Bleeding

Radiator Not Heating Up After Bleeding

A radiator that worked until you bled it, or that stays cold afterwards, nearly always comes down to boiler pressure, a valve or air that has moved. Check in that order.

Low risk · Fixed by a heating engineer

Blake FolgadoBlake Folgado, Co-founder, TradehandPublished Updated

Key takeaways

  • Look at the boiler pressure gauge first: bleeding can drop it too low.
  • Top it up via the filling loop to the boiler's normal range, usually 1 to 1.5 bar.
  • Check the thermostatic valve and the lockshield valve are both open.
  • Cold at the bottom after all that points to sludge. That needs an engineer.

What's happening?

Bleeding a radiator lets trapped air out through the vent, and some water comes with it. On a sealed system that water is not replaced automatically, so the pressure on the boiler gauge falls. EDF Energy says low boiler pressure can stop the heating working across several radiators, because the boiler cannot provide the hot water needed. Vaillant gives the target as around 1 to 1.5 bar for its boilers, and says to check your manual because it varies by model. The air that was in the radiator can also move to another point in the system after the first bleed, so a second bleed is often needed once pressure is restored.

What usually causes it?

  • Boiler pressure dropped below the working range after bleeding
  • Air that has moved to another radiator or the top of the system
  • A thermostatic radiator valve or lockshield valve that was closed or moved
  • Sludge or debris, which leaves the bottom of the radiator cold
  • A leak that is losing water, so the pressure keeps falling
  • A stuck radiator valve pin that is not opening the valve

Is it dangerous?

Not dangerous. Bleed with the heating off and the radiator cool, because the water can be hot, and hold a cloth under the vent. Vaillant says if pressure falls again as soon as you close the filling valves, there is a significant leak or a fault, and you should stop topping up and call a Gas Safe registered engineer.

Can I fix it myself?

Check the pressure gauge. If it is below the boiler's range, repressurise with the filling loop: switch the boiler off and let it cool, check both ends of the loop are attached, open the isolation valve, open the handle valve and watch the gauge rise to about 1 to 1.5 bar, then close both again. Check the thermostatic valve and the lockshield valve are open on the radiator. Switch the heating on and bleed the radiator again if it is still cold at the top. EDF Energy says if it is still cold after all that, look for leaks and consider that the system may need flushing.

When should you call a heating engineer?

Call a heating engineer if the pressure drops again after repressurising, if the radiator is hot at the top and cold at the bottom after bleeding, if the valves will not move, or if several radiators stay cold. Cold at the bottom suggests sludge, and EDF Energy says a power flush should be done by a plumber rather than the homeowner.

What will the heating engineer actually do?

  • Check the pressure and where the system is losing water, if it is
  • Test whether the radiator valves are opening and replace a stuck pin or valve
  • Bleed the whole system and balance the radiators
  • Test the radiator and system for sludge and clean it with a chemical or power flush
  • Fit a magnetic filter and inhibitor to protect the system afterwards

Who fixes this

  • Heating not working
  • Power flush

Questions people ask

Why is my radiator cold after bleeding?

The most common reason is that boiler pressure fell when water came out with the air. Top it up via the filling loop. Also check both radiator valves are open, and bleed again, because air can move to another point.

How much pressure should the boiler have after bleeding?

Vaillant says to aim for around 1 to 1.5 bar, and to check your own boiler's manual because the recommended level can vary by model.

Do I bleed the radiator again after repressurising?

Often yes. EDF Energy says air can shift round the system after the first bleed, so check the pressure and bleed again.

What if the radiator is still cold at the bottom?

That points to sludge or debris sitting at the bottom of the radiator. EDF Energy says that needs a power flush by a plumber, not the homeowner.

Sources & References

  1. EDF Energy: noisy radiator or radiator not working
  2. Vaillant UK: how to repressurise a boiler