Boiler Keeps Breaking Down
Not sure? We'll check for you.
Medium
What's happening?
A boiler that keeps breaking down is not automatically a boiler that needs replacing. What decides it is whether the faults are the same one coming back, different parts wearing out, or a problem in the system around the boiler. The same fault returning suggests it was never properly diagnosed, or something upstream such as sludge, low pressure or a failing pump keeps causing it. Different parts failing one after another, on an old boiler, points to general wear. An engineer's fault history is the evidence.
What usually causes it?
- The same fault returning because the first repair treated a symptom
- Sludge or debris in the system restricting flow and overheating the boiler
- Pressure that keeps dropping because of a leak or a failing expansion vessel
- A worn pump, diverter valve or sensor on an older boiler
- A blocked condensate pipe or flue problem causing lockouts
- Controls, thermostats or wiring faults that look like boiler faults
- Parts that have worn out one after another because the boiler is old
Is it dangerous?
A boiler that locks out is protecting itself. The danger is in forcing it back on again and again, or ignoring signs of combustion trouble. If you smell fumes, see soot or staining, or a carbon monoxide alarm sounds, switch it off and get a Gas Safe registered engineer.
Can I fix it myself?
Keep a log of the date, the fault code and what the boiler was doing each time, and note the pressure gauge reading. That log is what lets an engineer see a pattern. Check pressure, thermostat batteries and open radiator valves, and reset once. Anything inside the boiler casing is gas work.
When should you call a heating engineer?
Call a Gas Safe registered engineer when the second breakdown has the same cause, when fault codes keep appearing, or when you are being asked to choose between another repair and a new boiler. Ask for the cause in writing, not just the part.
What will the heating engineer actually do?
- Read the fault history and codes and compare them with what you logged
- Check system pressure, flow, the pump and the condition of the water in the system
- Test the part the fault points to and replace it
- Clear the condensate trap and check the flue
- Recommend a system clean or filter where sludge is the cause
- Say plainly whether the boiler is worth repairing again, and what replacing would involve
Who fixes this
- Boiler repair
- Power flush
- Boiler installation
What it usually costs
- Power Flush Cost
- £400–£870
- New Boiler Cost
- £1,400–£7,000
Questions people ask
My boiler keeps breaking down, do I need a new one?
Why does my boiler keep breaking down after being repaired?
Is boiler cover worth it if mine keeps breaking?
When is a boiler too old to repair?
Sources & References
Before you book, read how to check a heating engineer is registered.