Boiler Clicking But Won't Fire

The clicking is the boiler's igniter sparking. If there is no flame after a few tries it locks out. Check the gas is on and reset once, then call.
Blake Folgado, Co-founder, TradehandPublished
How urgent
Caution
Who fixes it
A heating engineer

What's happening?

When the boiler is called for heat it runs the fan, opens the gas valve and sparks an electrode at the burner. The clicking you hear is that spark. If the gas lights, the clicking stops and the boiler runs. If it does not, the boiler tries a few more times, then locks out with a red light or a fault code and waits for a reset. So clicking without a flame means either no gas is reaching the burner, the spark is too weak or in the wrong place, the gas valve is not opening, or the boiler cannot prove it is safe to light, because the fan or flue is blocked. The fault code for this stage differs by make, so look it up in the manual.

What usually causes it?

  • No gas reaching the boiler: a closed gas tap, an empty prepayment meter or a supply fault
  • A dirty, worn or misaligned ignition electrode, or a damaged ignition lead
  • A gas valve or its coil that is not opening
  • A weak flame sensing rod that cannot confirm the flame
  • A blocked condensate pipe or flue that stops the safety switches closing
  • A failed fan or air pressure switch, so the boiler never reaches the lighting stage
  • A circuit board that no longer sequences the start

Is it dangerous?

Medium. Unburnt gas can collect briefly when a boiler sparks without lighting, which is why it limits its own attempts. Do not override that. If you smell gas, leave the property, open doors on the way out and call the National Gas Emergency Service on 0800 111 999 (0800 002 001 in Northern Ireland). A boiler that keeps locking out should stay off.

Can I fix it myself?

Check that the gas tap at the boiler is open and that the hob works, which shows gas is reaching the house. On a prepayment meter, check the credit. Check the condensate pipe is not frozen in cold weather. Then reset once using the button in the manual. Do not reset more than twice and do not open the casing: electrodes, gas valves and fans are all gas work.

When should you call a heating engineer?

Call a Gas Safe registered engineer if the boiler still clicks without lighting after one reset, if it locks out again, or if it has shown the same code more than once. The engineer needs the exact code and when it appears.

What will the heating engineer actually do?

  • Read the fault history and watch a full start sequence
  • Check gas inlet pressure and working pressure at the boiler
  • Inspect, clean or replace the ignition electrode and lead
  • Test the gas valve, flame sensor, fan and pressure switch
  • Clear and test the condensate trap and check the flue
  • Leave the boiler lighting first time through a full heating and hot water call

Who fixes this

Questions people ask

Why is my boiler clicking but not firing?

The igniter is sparking and the gas is not lighting, or the boiler is not letting gas through. No gas supply, a worn electrode and a gas valve fault are the usual reasons.

What does the red light on my boiler mean?

On most boilers a steady or flashing red light is a lockout: the boiler stopped for a fault and will not run until it is reset.

What does the fault code mean when my boiler clicks but does not light?

Codes differ by make and the manual lists yours. For this stage they are ignition or gas supply faults: the boiler tried to light and could not prove a flame. The causes are the ones on this page.

Is it safe to keep pressing the reset button?

No. Reset once or twice. Beyond that you are asking a boiler that cannot light to keep sending gas.