Skip to main content
Baxi E133 Fault Code

Baxi E133 Fault Code

E133 is a lockout: the boiler tried to light, did not get a flame it trusted and shut itself down. The red lockout light shows with it.

Caution · Fixed by a heating engineer

Sol WrightSol Wright, Co-founder, TradehandPublished Updated

Key takeaways

  • Check gas is reaching the house and a prepayment meter has credit.
  • Reset the boiler once using the method for your model.
  • If it returns, a frozen condensate pipe or an ignition part is the likely cause.
  • Frequent lockout means a fault: call a Gas Safe registered engineer.

What's happening?

Baxi's own advice says E133 indicates a problem with either the gas supply, ignition or flame, or a blocked condensate. The boiler runs its start sequence, fan first, then gas and spark. If it does not detect a flame it tries again a few times and then locks out, which Baxi describes as the red lockout light staying on or flashing. The boiler is protecting itself and you: it will not keep releasing gas that is not burning. A one-off E133 after a gas supply interruption, a prepayment meter running out or a cold night is common. One that returns after resets is a fault that needs an engineer.

What usually causes it?

  • No gas reaching the boiler: meter off, supply interruption, or prepayment credit run out
  • A blocked or frozen condensate pipe in cold weather
  • A dirty or damaged ignition electrode or lead that will not spark
  • A flame sensing probe that is not recognising the flame
  • A faulty gas valve not opening, or low gas pressure
  • Air or flue trouble stopping a clean ignition

Is it dangerous?

E133 itself is a safety shutdown, not an emergency. If you smell gas, do not reset: turn off the gas at the meter, open windows, leave the house and call the National Gas Helpline on 0800 111 999. Do not keep resetting a lockout again and again, because each reset tries to light the boiler again.

Can I fix it myself?

Check that other gas appliances work and, on a prepayment meter, that there is credit. Look at the condensate pipe outside in cold weather: if it is frozen, that is likely the cause and a heating engineer can thaw it safely. Then reset the boiler once. Baxi's method depends on the controls: press the reset button until the red light goes out; or turn the control knob fully anticlockwise and hold it until the light goes out; or turn the selector switch to R and hold it for at least 5 seconds. Do not open the boiler casing.

When should you call a heating engineer?

Call a Gas Safe registered engineer if E133 returns after a reset, if lockout happens frequently, if the gas supply is fine and the condensate pipe is clear, or if you can hear the boiler clicking without lighting. Baxi says frequent lockout indicates a fault and you should contact your installer or service engineer.

What will the heating engineer actually do?

  • Read the fault history and confirm the lockout cause
  • Check the gas supply pressure and that the gas valve opens
  • Inspect, clean or replace the ignition electrode and flame sensing probe
  • Check the condensate trap and discharge pipe for blockage or ice
  • Test combustion and flue, then re-run the ignition sequence

Who fixes this

What it usually costs

Questions people ask

What does E133 mean on a Baxi boiler?

Baxi says it indicates a problem with the gas supply, ignition or flame, or a blocked condensate. The boiler could not establish a flame and has locked out.

How do I reset a Baxi boiler with E133?

It depends on the controls: press the reset button until the red light goes out, or turn the knob fully anticlockwise and hold it until it clears, or turn the selector switch to R for at least 5 seconds. Reset once, not repeatedly.

Can a frozen condensate pipe cause E133?

Yes. Baxi lists a blocked condensate as one of the causes. In cold weather the outside condensate pipe can freeze and stop the boiler firing.

Why does E133 keep coming back?

Because the cause is still there. Baxi says frequent lockout indicates a fault. An engineer needs to check the gas supply, the ignition electrode and probe, and the condensate pipe.

Sources & References

  1. Baxi: how to reset a Baxi boiler
  2. NHS: carbon monoxide poisoning

Need a heating engineer?

Describe the job and get a fixed price from a local heating engineer.

Get a quote