Baxi E133 Fault Code
How much to fix yours?
Usually £156
Caution · Fixed by a heating engineer
Key takeaways
- Check gas is reaching the house and a prepayment meter has credit.
- Reset the boiler once using the method for your model.
- If it returns, a frozen condensate pipe or an ignition part is the likely cause.
- Frequent lockout means a fault: call a Gas Safe registered engineer.
What's happening?
Baxi's own advice says E133 indicates a problem with either the gas supply, ignition or flame, or a blocked condensate. The boiler runs its start sequence, fan first, then gas and spark. If it does not detect a flame it tries again a few times and then locks out, which Baxi describes as the red lockout light staying on or flashing. The boiler is protecting itself and you: it will not keep releasing gas that is not burning. A one-off E133 after a gas supply interruption, a prepayment meter running out or a cold night is common. One that returns after resets is a fault that needs an engineer.
What usually causes it?
- No gas reaching the boiler: meter off, supply interruption, or prepayment credit run out
- A blocked or frozen condensate pipe in cold weather
- A dirty or damaged ignition electrode or lead that will not spark
- A flame sensing probe that is not recognising the flame
- A faulty gas valve not opening, or low gas pressure
- Air or flue trouble stopping a clean ignition
Is it dangerous?
E133 itself is a safety shutdown, not an emergency. If you smell gas, do not reset: turn off the gas at the meter, open windows, leave the house and call the National Gas Helpline on 0800 111 999. Do not keep resetting a lockout again and again, because each reset tries to light the boiler again.
Can I fix it myself?
Check that other gas appliances work and, on a prepayment meter, that there is credit. Look at the condensate pipe outside in cold weather: if it is frozen, that is likely the cause and a heating engineer can thaw it safely. Then reset the boiler once. Baxi's method depends on the controls: press the reset button until the red light goes out; or turn the control knob fully anticlockwise and hold it until the light goes out; or turn the selector switch to R and hold it for at least 5 seconds. Do not open the boiler casing.
When should you call a heating engineer?
Call a Gas Safe registered engineer if E133 returns after a reset, if lockout happens frequently, if the gas supply is fine and the condensate pipe is clear, or if you can hear the boiler clicking without lighting. Baxi says frequent lockout indicates a fault and you should contact your installer or service engineer.
What will the heating engineer actually do?
- Read the fault history and confirm the lockout cause
- Check the gas supply pressure and that the gas valve opens
- Inspect, clean or replace the ignition electrode and flame sensing probe
- Check the condensate trap and discharge pipe for blockage or ice
- Test combustion and flue, then re-run the ignition sequence
Who fixes this
What it usually costs
Questions people ask
What does E133 mean on a Baxi boiler?
How do I reset a Baxi boiler with E133?
Can a frozen condensate pipe cause E133?
Why does E133 keep coming back?
Sources & References
Before you book, read how to check a heating engineer is registered.