Skip to main content
Loft Conversion Too Hot In Summer: Do I Need Air Conditioning?

Loft Conversion Too Hot In Summer: Do I Need Air Conditioning?

Not sure? We'll check for you.

Short answer: air conditioning is the last resort for a hot loft room. Shade the windows, let heat out and check the roof insulation first, then have a split system fitted by an F gas certified installer if it is still too hot.

Low

Blake FolgadoUpdated

What's happening?

A loft room sits directly under the roof, so it takes the sun's heat from above and from the roof windows. GOV.UK's guidance says Approved Document O, the overheating rule in the Building Regulations, applies to new residential buildings only, so it does not set the standard for an existing house. That guidance also says passive measures, such as limiting solar gain and removing heat, should be adopted before installing mechanical cooling. For your loft, that means shading the glazing and ventilating first. If it still overheats, an air conditioning installer can fit a split system that cools the room.

What usually causes it?

  • Roof windows with no blinds or shading, so the sun heats the room all day
  • Little or no way to ventilate, so hot air cannot escape
  • Roof insulation that falls short of what Approved Document L expects for a converted loft
  • A south or west facing roof slope taking the afternoon sun
  • Large areas of glazing with no solar control
  • A room with no cross ventilation from another opening

Is it dangerous?

A room too hot to sleep in is mainly a comfort problem. In a heatwave, move anyone sleeping there to a cooler room, and do not leave a child or a pet in a closed, hot room.

Can I fix it myself?

Start with the passive steps GOV.UK says to try before mechanical cooling. Fit external or internal blinds on roof windows and draw them before the sun reaches the room. Open windows and doors at night and in the early morning for a draught through the house. Use fans to move air, not as a substitute for ventilation. Ask whoever did the conversion for the building control completion certificate and any insulation details.

When should you call an air conditioning engineer?

Call an air conditioning installer when shading and ventilation have not been enough. Approved Document L says retained roof elements in a loft conversion should be upgraded if the U-value is above its threshold, so a builder can check the insulation too. The installer must be certified: GOV.UK says companies must be certified to install stationary air conditioning containing F gas. Ask for the certificate and a written quote.

What will the air conditioning engineer actually do?

  • Look at the room, the roof glazing, the orientation and what shading or ventilation is in place
  • Size a split system to the room's heat load and choose where the indoor and outdoor units go
  • Install the indoor unit, outdoor unit, pipework and condensate drain
  • Connect the electrical supply with a protective device suitable for the unit, and commission the system
  • Pressure-test and leak-check the refrigerant circuit and record the refrigerant used
  • Show you how to run it and keep the filters clean

Who fixes this

What it usually costs

Questions people ask

Why is my loft conversion so hot in summer?

A loft room sits under the roof and takes heat through the roof and its windows. Large glazing with no shade, poor ventilation and a south facing slope all add to it. GOV.UK's guidance on overheating says to limit solar gain and remove heat before adding mechanical cooling.

Does Approved Document O apply to my loft conversion?

GOV.UK says Part O only applies to new residential buildings and does not apply to buildings undergoing a change of use. So it does not set the standard for an existing house. Approved Document L does cover insulation in a loft conversion.

Do I need air conditioning in my loft room?

Not always. GOV.UK's guidance says passive measures, like shading and ventilation, should be tried first. If the room is still too hot, a split system is a reasonable next step.

Who can install air conditioning?

A company certified to install stationary air conditioning containing F gas. GOV.UK says companies must be certified by an approved body, so ask to see the certificate before you accept a quote.

Sources & References

  1. GOV.UK: Approved Document O, overheating, frequently asked questions
  2. GOV.UK: Approved Document O (overheating)
  3. GOV.UK: Approved Document L (conservation of fuel and power)
  4. GOV.UK: Certification for companies working on equipment containing F gas