Kitchen Under-Cabinet Lights Not Working
Low risk · Fixed by an electrician
What's happening?
Under-cabinet lighting is normally extra-low voltage. Electrical Safety First describes low-voltage lighting as supplied through a transformer or driver at about 12 V, which is why the lights are fed from a small box rather than straight from the mains. That box is the most common failure. What happened tells you where to look. If the whole run is dead, suspect the driver, its supply or the switch. If one light is dead and the rest work, suspect that lamp or its connector. If the lights flicker or cut out when you use a dimmer, the lamps and the dimmer may not suit each other. Mains-side checks and any work inside the driver are for an electrician, because the driver is wired to the kitchen's lighting supply.
What usually causes it?
- The driver or transformer feeding the lights has failed, so the whole run goes dark together
- The supply to the driver has been lost, through a tripped breaker, a switched-off isolator or a switch fault
- A lamp that is not compatible with the driver, since Electrical Safety First says replacement lamps and components must suit the fitting and driver
- LED lamps that are not suitable for dimming on a dimmer switch
- A loose or corroded connector between the driver and the light
- A single failed lamp, where the rest of the run still works
Is it dangerous?
Dead under-cabinet lights are not dangerous. The driver is connected to mains, though, and sits in or behind a cupboard where heat and combustible material are close, so switch off the supply before touching anything, and do not open the driver. If a fitting or driver is scorched, hot or smells of burning, turn it off at the consumer unit and have it checked.
Can I fix it myself?
1. Check the light switch and any dimmer first, and check the kitchen lighting breaker has not tripped. 2. If only one light is dead, switch the supply off and check its lamp is fitted properly and is the type and wattage marked on the fitting. 3. If the lights are on a dimmer, check the lamps are marked as suitable for dimming. 4. Look for scorching or discolouration on the lights and around the driver without opening it. 5. If the whole run stays dead, leave it and book an electrician.
When should you call an electrician?
Call an electrician if the whole run is dead and the breaker and switch are fine, if the driver is hot or marked by heat, if the lights flicker on a dimmer, or if the lights stop working after a new fitting went in. Book the same day for burning smells.
What will the electrician actually do?
- Isolate the circuit and test for supply at the switch, the driver input and the driver output
- Replace a failed driver or transformer with one matched to the lights' voltage and total wattage
- Check lamps are compatible with the driver, and with a dimmer where one is fitted
- Re-make loose or corroded connections and replace damaged light fittings
- Test the circuit before handing the lighting back
Who fixes this
What it usually costs
- Lighting Installation Cost
- £50–£200 per light fitting
- Electrical Fault Finding Cost
- Priced on survey
Questions people ask
Why have all my kitchen under-cabinet lights stopped working at once?
Can I replace an under-cabinet LED with any LED?
Why do my under-cabinet lights flicker on the dimmer?
Is it safe to change the lamp myself?