Skip to main content
Microbore Pipework Problems

Microbore Pipework Problems

Not sure? We'll check for you.

Microbore pipes are not a fault by themselves. Sludge blocks narrow pipework first, so a clean and a filter come before re-piping.

Low

Blake FolgadoUpdated

What's happening?

Microbore heating runs a thin pipe from a manifold to each radiator, instead of larger pipes round the house. The trouble people report is cold radiators or a house that never warms up. Baxi says that if sludge builds up it can block pipes, make radiators inefficient and damage parts in the boiler. Its signs include radiators hot at the top and cold at the bottom, pipework to a radiator that is hot while the radiator is not, and a flow pipe that is hot while the return is lukewarm or cold. Narrow pipes have less room for sludge before they restrict, so they show it sooner. A heating engineer tests the water and traces the blocked runs. Re-piping in larger pipe is the big job, and it is only the answer when cleaning does not hold.

What usually causes it?

  • Sludge and rust building up in the narrow pipes
  • No filter on the system to catch it
  • One run to a radiator blocked or kinked
  • A leak at a joint on a thin copper pipe
  • Air trapped at a radiator or on the manifold
  • A boiler or pump that is working harder against restricted flow

Is it dangerous?

Not a safety risk by itself. Baxi says sludge can damage the boiler, pump, radiators and valves, and that a breakdown caused by sludge is not covered by the boiler warranty.

Can I fix it myself?

Bleed the cold radiators. Feel which pipes are hot and which radiators stay cold, and whether the flow and return at the boiler are both hot. Check your last boiler service record shows a test of the system water, which Baxi says an installer should do at the annual service. Do not drain the system or add chemicals without knowing what is in it.

When should you call a heating engineer?

Call a heating engineer when the same radiators stay cold after bleeding, when the pipe to a radiator is hot but the radiator is not, or when a joint is leaking. Before a new boiler goes on a microbore system, ask whether the system will be cleaned and a filter fitted, since leftover sludge goes straight to the new boiler.

What will the heating engineer actually do?

  • Test the system water and find which radiators and runs are restricted
  • Clean the system with a method suited to narrow pipework, and say what happens if a run stays blocked
  • Fit a magnetic filter and refill with inhibitor so the sludge does not return
  • Replace a blocked or leaking run with new pipe
  • Re-pipe in larger diameter pipe where cleaning does not hold, if you agree to it
  • Balance the radiators and check the flow and return temperatures

Who fixes this

What it usually costs

Power Flush Cost
£400–£870

Questions people ask

Should I replace microbore pipes?

Not just because they are microbore. If every radiator heats up and the water is clean, there is nothing to replace. Replace the runs that stay blocked or keep leaking after the system has been cleaned.

Why are my radiators cold with microbore pipes?

The usual cause is sludge. Baxi lists radiators hot at the top and cold at the bottom, a hot pipe feeding a cold radiator and a lukewarm return as signs. A water test and a clean come first.

Can microbore pipes be power flushed?

It depends on the system, and the engineer decides. Ask them which method they will use and what they will do if one run stays blocked, because narrow pipes are quicker to restrict.

Does a new boiler need the microbore pipework replaced?

Not automatically. The system should be cleaned and a filter fitted, because Baxi says sludge damages boiler parts and that sludge damage is not covered by the warranty.

Sources & References

  1. Baxi: why should I get the water in my central heating system cleaned?
  2. Baxi: how do I know if I've got sludge in my central heating system?