Combi Boiler Not Enough Hot Water For A Bath
Not sure? We'll check for you.
Low
What's happening?
A combi boiler heats water only as you use it. Vaillant says that on an average combi only one tap or outlet works well at a time, that larger homes with several bathrooms need hot water faster than a combi can heat it, and that a system boiler with a cylinder is often more suitable there because it stores hot water and can supply several outlets at once. It also says combis suit one bathroom and one to three bedrooms. So a bath that runs lukewarm, or a shower that weakens when the bath is filling, can be the boiler working as designed in a house it is too small for. This is different from hot water going cold mid-shower, which is a fault covered on its own page. What decides it is how many outlets run at once and how good the mains supply is.
What usually causes it?
- A combi fitted in a house with more than one bathroom, or a larger household
- Two outlets, such as a bath and a shower, running at the same time
- Mains flow too low for the boiler to give its rated output
- The hot water temperature set low on the boiler
- A bath tap or shower mixer that restricts flow
- A boiler that has lost output through scale or a fault, which is a repair rather than a replacement
Is it dangerous?
No. A combi that cannot keep up is a comfort problem. If the boiler is also showing a fault code, cutting out or leaking, that is covered elsewhere and needs a Gas Safe engineer.
Can I fix it myself?
Check the hot water temperature setting on the boiler, run only the bath and see whether it holds its temperature, and see whether it improves when nothing else is running. Anything inside the boiler is Gas Safe work. A Gas Safe registered engineer can tell you whether it is the boiler or the supply.
When should you call a heating engineer?
Call a Gas Safe registered heating engineer when the bath is lukewarm with nothing else running, or when a household has grown and the combi has not. Ask them to measure the flow and output at the bath tap and tell you whether the boiler is faulty or simply too small for the use.
What will the heating engineer actually do?
- Measure the flow rate and temperature at the bath tap with the boiler at full output
- Check the boiler's settings, service history and heat exchanger for a fault that cuts output
- Check the mains flow and pressure the combi is getting
- Say whether the boiler is working as designed, whether a repair would restore output, or whether the house needs stored hot water
- Quote a system boiler and cylinder if that fits the household better, including where the cylinder would go
Who fixes this
- Boiler installation
- Hot water cylinder repair and replacement
What it usually costs
- New Boiler Cost
- £1,400–£7,000
- Hot Water Cylinder Replacement Cost
- £350–£1,000
Questions people ask
Why does my combi boiler not give enough hot water for a bath?
Is my boiler too small for my house?
Would a hot water cylinder fix it?
Does low water pressure affect a combi?
Sources & References
Before you book, read how to check a heating engineer is registered.