Air Conditioner Keeps Tripping The Breaker

Air Conditioner Keeps Tripping The Breaker

The breaker, fuse or RCD for the air conditioner trips as soon as it starts, or after it has been running for a while.

Caution · Fixed by an air conditioning engineer

Updated

What's happening?

An air conditioner that trips its protection is telling you that the unit, the circuit or the protective device is not coping. iHeat, a UK installer, lists faulty wiring, blown fuses and tripped circuit breakers among the electrical faults that can stop an air conditioner starting, and advises checking the breaker, cleaning or replacing dirty filters and clearing debris round the outdoor unit. Electrical Safety First says that if an RCD keeps tripping there is likely to be a fault, with either an appliance or the wiring, that a registered electrician should investigate. Split systems normally have a separate supply for the indoor and the outdoor unit, so noting which device trips and when helps the engineer. A trip at the moment of starting and a trip after running for a while point to different faults. Resetting again and again is not a repair.

What usually causes it?

  • A fault in the unit's wiring or an electrical component
  • A fault in the supply circuit or the protective device itself
  • Dirty filters or debris round the outdoor unit restricting airflow
  • A problem with the compressor or another outdoor component
  • A damaged cable or loose connection

Is it dangerous?

A repeat trip is a protective device doing its job, and resetting it repeatedly is not a repair. Do not keep resetting, do not bypass the breaker and do not open the unit. If the trip comes with a burning smell, see the page on burning smells.

Can I fix it myself?

1. Switch the air conditioner off at the remote and the isolator. 2. Reset the breaker once, and try the unit once. If it trips again, stop. 3. Note which breaker trips, and whether it is at start-up or after running. 4. Check the outdoor unit for visible water, debris or damage, without opening it. 5. Clean the indoor filters, which can help if overheating is the cause. 6. Do not swap the breaker for a bigger one.

When should you call an air conditioning engineer?

Call an air conditioning engineer if it trips more than once, trips with water on the outdoor unit, or trips on start-up every time. Call an electrician if the fault seems to be in the circuit or the protective device rather than the unit.

What will the air conditioning engineer actually do?

  • Work out which circuit and which protective device trips, and when
  • Test the unit's insulation to earth and its current draw at start and run
  • Check the compressor, fan motors, wiring and connections for faults
  • Clean the filters and clear airflow round the outdoor unit
  • Refer a circuit or protective device fault to an electrician for correction

Who fixes this

Questions people ask

Why does my air conditioner trip the breaker?

It may be a fault in the unit's wiring or components, a fault in the circuit, or restricted airflow. Whether it trips at start-up or after a while helps the engineer find which.

Can I fit a bigger breaker?

No. Electrical Safety First says a repeatedly tripping device points to a fault that a registered electrician should investigate, so changing the device without finding the fault is unsafe.

How often should I test my RCD?

The IET says operating the test button gives assurance that an RCD works, and the current BS 7671 label asks for it every six months.

Sources & References

  1. Electrical Safety First: Your questions answered
  2. iHeat: Air conditioning unit, common errors and fixes
  3. IET: BS 7671 FAQs, consumer units and protective devices

Need an air conditioning engineer?

Describe the job and get a fixed price from a local air conditioning engineer.