Free Socket Load Calculator
Check if you are overloading a socket or extension lead. Select the appliances plugged in to see the total wattage and whether it is safe.
This socket load calculator helps you check whether the combination of appliances plugged into a single socket or extension lead exceeds the safe limit. A standard UK 13A socket can handle up to 3,000 watts. Overloading sockets is one of the leading causes of electrical fires in the UK: use this tool to check before you plug in.

Socket Load Calculator results
Fill in the details and select Calculate to see your figures.
Win more of the jobs you quote.
Tradehand is the software your trade business runs on, with an assistant that answers every call and message, sends your quotes the same day and chases them until they land. The first £10,000 Tradehand collects for a business carries no Tradehand fee. After that, Tradehand earns 5% of collected invoice payments. No monthly fee, setup fee, card fee or contract.
Get startedHow to use the Socket Load Calculator
- 1Toggle on each appliance that is plugged into the same socket or extension lead.
- 2Check the total wattage against the 3,000W maximum for a standard UK 13A socket.
- 3If the status shows 'Warning' or 'Danger', unplug high-wattage appliances and spread them across different sockets.
- 4Never plug one extension lead into another (daisy-chaining) as this increases fire risk.
How the Socket Load Calculator works
The safe limit of a socket or extension lead is set by current (amps), not wattage directly. Convert each appliance's wattage to the current it draws at the UK mains voltage of 230 V, add them up, and compare against the fuse rating.
- Kettle 3,000 W ÷ 230 V = 13.0 A: on its own it already uses the full 13 A fuse.
- Hair dryer 2,200 W ÷ 230 V = 9.6 A, plus a fan heater 3,000 W ÷ 230 V = 13.0 A → 22.6 A combined.
- 22.6 A is well over the 13 A fuse in a single socket or 4-way lead, so that combination is unsafe.
- Low-power items are fine: a 60 W lamp draws 0.26 A and a 5 W charger draws 0.02 A.
This is the socket/extension-lead limit (one 13 A BS 1363 fuse). It is separate from the circuit behind the wall: a ring final circuit is protected at 32 A and a radial at 20 A or 32 A, and BS 7671 applies diversity (an allowance that not every point runs at full load at once) when designing those circuits. This tool only checks a single socket outlet. If you are sizing a circuit, use a qualified electrician.
Typical UK benchmarks
| UK Socket Limit (13A) | 3,000W max, BS 1363 |
| Extension Lead Limit | Most 4-way leads rated at 13A / 3,000W, same BS 1363 fuse rating |
Disclaimer
This tool gives an estimate for general guidance only, based on typical UK figures and the details you enter. It is not a formal quote, survey, or professional advice. Always confirm with a qualified tradesperson before relying on any figure, as regional prices, site conditions, and current standards vary.
You do the job, Tradehand handles everything around it.
Your assistant sends the quotes, chases the invoices, books the work and keeps your customers updated. The first £10,000 Tradehand collects for a business carries no Tradehand fee. After that, Tradehand earns 5% of collected invoice payments. No monthly fee, setup fee, card fee or contract. One office hire costs about £25,000 a year, whether the invoices land or not.