The RCD or breaker protecting the solar system trips in wet weather, at dawn or dusk, or as soon as the inverter starts.

Caution · Fixed by a renewable energy installer

Updated

What's happening?

An RCD trips when it sees current flowing to earth that should have returned through the circuit, and the IET lists solar photovoltaic power supplies among the installations that need RCD protection. The inverter turns the DC from the panels into AC for the house. The IET says some inverters give no electrical separation between the AC supply and the DC side of the array, and that in that case some manufacturers' instructions require a Type B RCD, because a DC fault current can blind an ordinary Type AC device. A trip can therefore be a mismatch between the inverter and the RCD, or a real leakage fault. BRE's fire investigations list moisture ingress in connectors and junction boxes among the causes of faults on PV systems, which is why wet weather is worth noting. Which device suits the circuit is an electrician's decision.

What usually causes it?

  • Moisture that has got into DC connectors, junction boxes or switches on the array
  • A DC cable or connector with damaged insulation or poor contact
  • A cracked or damaged panel, or a faulty component inside a module
  • An RCD of a type that does not suit an inverter with no electrical separation
  • A faulty inverter
  • An earth fault on the AC side of the installation, unrelated to the panels

Is it dangerous?

An RCD that trips on a solar circuit may be reacting to a real leakage fault, and a damaged DC cable can be dangerous because an array produces power whenever it is light. Do not reset it repeatedly, bypass it or open the isolator or inverter. Do not go onto the roof.

Can I fix it myself?

1. Note when it trips: dry or wet weather, morning or evening, when the inverter starts. 2. Reset it once. If it trips again, leave it off and tell your installer. 3. Do not swap the RCD for a different rating. 4. Do not open the inverter, the DC isolator or the connectors. 5. Do not climb on the roof. 6. Contact the installer first if the system is under warranty or MCS certified.

When should you call a renewable energy installer?

Call your installer or a qualified electrician, ideally with solar experience, if the RCD trips more than once, trips in wet weather, or you see damage or scorching. Call 999 for fire or smoke.

What will the renewable energy installer actually do?

  • Isolate the array and test insulation resistance on the DC strings and the AC side
  • Check connectors, junction boxes and cables for water, damage and poor terminations
  • Check the inverter's leakage current and fault log against the protective device
  • Provide separate, correctly rated and typed protection for the solar circuit
  • Repair or replace damaged cables, connectors, panels or the inverter

Who fixes this

  • Solar panel system check
  • Solar inverter replacement

Questions people ask

Why do my solar panels trip the RCD when it rains?

Damp can get into connectors and junction boxes, which BRE's fire investigations record as a cause of PV faults, and an inverter with no electrical separation may need a Type B RCD according to the IET. Testing shows whether it is damp, a fault or a mismatch.

Can I just fit a less sensitive RCD?

No. The device and type are an electrician's decision, because RCDs protect people from shock, and the IET says manufacturers must define which RCD types suit equipment with inverters.

Is it safe to keep resetting it?

No. Reset once, and if it trips again, switch off and call your installer or an electrician.