Solar Generation Meter Stopped, Flashing Or Not Counting

Solar Generation Meter Stopped, Flashing Or Not Counting

The meter that counts what the panels generate is blank, flashing, stuck or has stopped counting while the inverter shows output.

Low risk · Fixed by a renewable energy installer

Updated

What's happening?

The generation meter is the one that records how many kilowatt hours the panels produce, usually a small meter near the consumer unit or the inverter, separate from the supplier's import and export meter. On many older systems it is the meter the feed-in tariff relied on: Ofgem says FIT payments are based on meter readings that generators submit to their licensee, and licensees verify the readings. A meter that has gone blank, is flashing or has stopped counting while the inverter still shows output means the system is generating but the record is not. That matters for older FIT payments and for knowing how the array is performing. It can be a meter fault, a lost supply, a loose connection or a meter that was never set up properly. Newer Smart Export Guarantee systems rely on export readings from a smart meter instead.

What usually causes it?

  • A fault in the generation meter itself, or its display
  • A loose or failed connection to the meter's supply or current clamp
  • A tripped breaker or isolator removing the supply to the meter
  • An inverter that is not communicating or is not generating, so there is nothing to count
  • A meter that was replaced or reset and not recorded properly
  • A meter that was never correctly wired in at installation

Is it dangerous?

A generation meter that is flashing or stopped is not itself dangerous, but a meter or isolator that is hot, scorched or smelling of burning is an electrical fault, so switch off and call an electrician. Do not open the meter or tamper with its seals.

Can I fix it myself?

1. Read the meter and the inverter display and compare them. 2. Check whether the isolator or breaker supplying the meter is on. 3. Photograph the meter display, with the date, and keep any past readings. 4. Do not open or tamper with the meter. 5. If you are on an older FIT arrangement, check what your licensee says about missing readings. 6. Tell the installer if the system is still under warranty.

When should you call a renewable energy installer?

Call a solar engineer or your installer if the meter is blank, flashing, stuck or disagrees with the inverter, or if it is warm or scorched. Say whether you are on FIT or SEG, so they know which readings matter.

What will the renewable energy installer actually do?

  • Compare the generation meter, the inverter output and the monitoring
  • Check the supply, the isolators and the connections feeding the meter
  • Test the system output and confirm the array and inverter are generating normally
  • Replace a faulty meter or reconnect it, with a record of the readings
  • Provide a performance report to support a FIT or SEG query

Who fixes this

  • Solar panel system check

Questions people ask

Why has my solar generation meter stopped?

It could be a meter fault, a lost supply, a loose connection, or the system not generating. Compare the meter with the inverter display to see which.

Does a faulty generation meter affect my payments?

It can on older FIT systems, because Ofgem says FIT payments are based on meter readings that generators submit. Tell your licensee and keep records.

Is my SEG payment based on the generation meter?

Not usually. GOV.UK says you need a meter capable of half-hourly export readings, typically a smart meter, to apply for a SEG tariff.